Lasting accuracy for diaphragm seal systems for vacuum process

A diaphragm seal system in vacuum pressure process must master a major challenge ? it must deliver a reliable measuring result, even when the pressure drops and the temperature rises as well. The exemplory case of a chemical company producing phthalic anhydride (PA) implies that it is in no way self-evident that requirement can be met on a consistent basis.
PA is primarily used as a plasticiser for plastics. However, it is also used in the production of synthetic resins and dyes. The plant operator obtains this compound via the catalytic oxidation of o-xylene in the gas phase, accompanied by a vacuum distillation process.
Critical phase for pressure measurement
In this technique, the critical phase for pressure measurement occurs in the distillation column. There, the procedure temperature can rise to a lot more than 230 �C while the pressure drops to 100 mbar abs. With such a contrary action, the conventional installed measurement technology reaches its performance limit relatively quickly, that your aforementioned manufacturer was forced to learn ? all instrumentation showed a measurement deviation outside the defined tolerance after only a fortnight.
Diaphragm seal system adapted in every elements to the vacuum process
The diaphragm seal system is tailored exactly to the conditions of the vacuum process and tested under application conditions.
Consequently, the business approached WIKA with the request for a measuring solution that could also fulfil its task with the mandatory accuracy in the long run beneath the conditions described. WIKA then drew on its in-depth expertise to design a diaphragm seal system for the vacuum process, comprising a process transmitter (model IPT-20), a flange-type diaphragm seal with flush diaphragm (model 990.27) and a capillary.
All components of this measuring system were selected specifically for the application. Silicone oil KN32 was therefore selected because the fill fluid for pressure transmission. The cleaning and conditioning of the diaphragm seal, the capillary, the connection pieces and also the automated filling process were also matched to one another exactly. With sensitive limit ranges, even one drop of liquid an excessive amount of or inadequate can destabilise the volume balance of the diaphragm seal system and therefore impair its function. Because of this, correct measurement would no more be guaranteed.
Shocking under application conditions
After cleaning, all parts of the diaphragm seal system were first fully welded right into a single unit as usual, accompanied by the filling and adjustment of the machine. Before delivery, however, there is another crucial step ? in its laboratory, WIKA simulated a vacuum process for the diaphragm seal system in accordance with the customer?s conditions and subjected it to a thermal ageing process. This test confirmed the procedure suitability of the measuring system.
Note
More info on the WIKA diaphragm seal systems can be found on the WIKA website. If you have any questions, your contact will gladly help you.