Pressure sensor with I�C communication ? possibilities and boundary conditions

I�C was designed to communicate over short distances between printed circuit boards and is really a simple, 8-bit serial data bus. In the meantime, it isn’t only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but also pressure sensors remote from customer electronics.
Remote sensors usually have the advantage of being less sensitive to contaminated or aggressive media and having the capacity to measure directly at the process. In the case of sensors mounted on the circuit board, the sensor element is, oftentimes, exposed right to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside both supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is really a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than having an analogue signal:
In the data protocol, in addition to the pressure value, a temperature value and diagnostic information (for example an integrity test of the data transfer) could be transmitted via a status byte.
Several pressure sensors could be linked to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On the client side, as opposed to the utilization of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value is already present in digital form. This contributes to faster and easier signal processing.
The electronics for communication could be constructed with standard components easily available on the market.
Often, I�C signal pressure sensors are also optimised to take less energy, making them ideal for battery-powered applications. In Light , for example, this applies to the MPR-1 pressure sensor module.
Boundary conditions by using I�C
Since I�C isn’t a fieldbus, long wire lengths are not recommended. The maximum wire length depends, at length, on the operating environment and the corresponding disturbing influences. I�C communication is most beneficial used in projects where the pressure sensor or the pressure sensor module is integrated into the customer product and therefore protected against external influences. It should also be noted that with any digitally processed signal, the response time due to discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will be happy to help you with any further questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we’ll send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re committed to your privacy. We?ll use your information to contact you about our services. Contact us at socialmedia@wika.com to revoke your permission to utilize your information.

Leave a Comment